straightening-flame-torch-63.html
CW Product Cat UK
64 / 140
64 nozzle ma 3, flame straightening working pressure: oxygen 2
bar
8,500 l/h
acetylene
1
bar
lowest working pressure: oxygen 1.1
bar
5,400 l/h
acetylene
0.9
bar
heat output: 98 kw nozzle fa 6, pre-heating (raised working temperature) working pressure: oxygen 1.5
bar
10,000 l/h
acetylene
0.7
bar
lowest working pressure: oxygen 0.8
bar
6,400 l/h
acetylene
0.6
bar
heat output: 116 kw . aga no. / part no. flamtech torch 203 024 050 / 300469 nozzle ma 3 202 502 310 / 300611 nozzle fa 6 202 502 311 / 300616 nozzle fy 6 for thermolen ® 202 502 408 / 307990 rule of thumb for output of
acetylene
from various
cylinder
sizes.
cylinder
size content, filled
cylinder
maximum capacity a 5 0.8 kg equiv. to approx. 740 l 90 l/h a 20 3.1 kg equiv. to approx. 2,880 l 450 l/h a 40 7.8 kg equiv. to approx. 7,170 l 900 l/h bundle a 40 x 10 62 kg equiv. to 57,000 10,000 l/h rule of thumb for straightening and heating. material thickness x 2.5 x 100 = capacity of heating attachment e.g. material thickness: 20 mm x 2.5 x 100 = 15,000 l/h e.g. material thickness: 30 mm x 2.5 x 100 = 17,500 l/h e.g. material thickness: 40 mm x 2.5 x 100 = 10,000 l/h the
acetylene
gas supply to flamtech must take place from a
cylinder
bundle. in addition, double flashback arrestors, safe- guard-4, must be fitted with double outlets, as more than 5 m 3 /h of
acetylene
is required. note! → for a short period, larger nozzles can be connected to each gas
cylinder
→ a partially emptied gas
cylinder
reduces the capacity can be estimated as follows: –
cylinder
pressure x
cylinder
volume x 10 = approx. value of remaining gas volume. – example: 8
bar
x 40 (a 40
cylinder
) x 10 = approx. 3,200 litres of gas. torch systems. flame straightening. fa 6 ma 3 fy 6 for thermolen ® torch systems for further information, see page 128
cutting-torch-gas-65.html