77 additional information checklist / safe gas equipment yes no 1. regulator is the
gasket
in
good
condition? is there a spare
gasket
? is the regulator undamaged? 2. flashback protection is flashback protection in place? requirement for acetylene, recommended for oxygen connections ok? the flashback protection's functions must be tested every 24 months in accordance with ifs 1997:2 this must be performed by a workshop approved by the supplier. has a test been performed in the past 24 months? 3.
welding
hose are there any cracks? if so, replace the hose package is the
welding
hose suitable for the gas type? red ? acetylene blue ? oxygen orange ? lpg 4. non-return valve is there a non-return valve in the torch handle? perform the function check (blow from the rear) 5.
gasket
between handle and insert (only applies to combi torches) are the seat and the
gasket
in
good
condition? 6. cutting nozzle/
welding
attachment is the nozzle/insert undamaged? is the seat in
good
condition? 7. fire glove is there a fire glove? recommended 8. gas cylinders are the cylinders at no risk of tipping over (anchored)? 9. warning signs 10. test airtightness (leak-trace) of the entire equipment according to point 3 on the yellow card 11. yellow card "inspection instructions" secured to the equipment the inspections described above must be logged and archived according to the swedish
welding
commission template. this template can be downloaded from the swedish
welding
commission website, www.svets.se checklist.